Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Note

Note

  • For the new vNIOS for KVM models supported from NIOS 9.0.1 onwards, Infoblox recommends that you use SSDs for storage for better performance. See the tables in this topic for the supported models.

  • The specified Trinzic X6 series appliances running on NIOS 9.0.2 or later support the following features:

    • Virtual Advanced DNS Protection: All supported appliances of Trinzic X6 series.

    • Virtual DNS Cache Acceleration: IB-V2326 and IB-V4126 appliances.

  • If a Trinzic X5 vNIOS instance is running on a NIOS version prior to 9.0.1, the disk size will be set to 250 GB.

...

Network Insight Virtual Appliance

Overall Disk (GB)

# of vCPUs

Memory Allocation (GB)

Supported as Grid Master and Grid Master Candidate

ND-V805

500

2

32

No

ND-V1405

500

8

32

No

ND-V2205

500

16

64

No

ND-V4005

500

28

128

No

The following models of vNIOS for KVM appliances are supported in NIOS 9.0.1 and later:

Network Insight Virtual Appliance

Overall Disk (GB)

# of vCPUs

Memory Allocation (GB)

Supported as Grid Master and Grid Master Candidate

ND-V906

500

8

32

No

ND-V1606

500

16

64

No

ND-V2306

500

20

192

No

ND-V4106

500

32

384

No

...