The Infoblox 1405 Series platforms are 1-U appliances that you can efficiently mount in a standard equipment rack. For rack mounting information, see Rack Mounting Procedures .
...
Anchor | ||||
---|---|---|---|---|
|
View the Activity and Link LEDs to see link activity and connection speeds on Ethernet ports. Figure 2 describes the status conveyed by Ethernet port LEDs through their color and illumination (steady glow or blinking).
Anchor | ||||
---|---|---|---|---|
|
Anchor | ||||
---|---|---|---|---|
|
...
Anchor | ||||
---|---|---|---|---|
|
...
Infoblox 1405 Series rear panel components include the power connectors, hard disk drive, fans, and the UID LED, as shown in Figure 5.
Figure 5 Infoblox 1405 Series, Rear View Anchor bookmark f5 bookmark f5
Table 3 Infoblox 1405 Series Rear Panel Components
Component | Description |
---|---|
Fans | A fan system (up to six fans depending on the models) to help maintain optimum operating temperature. Do not obstruct. |
UID LED | Blue = UID is activated through pressing the UID button on the appliance Blinking Blue = UID is activated through the Grid Manager or CLI command Dark = UID is deactivated When UID is activated, the LCD on the front panel blinks at the same time. |
Power Supply | The 1405 Series appliances have two power supplies that provide redundancy. Each power supply has a power outlet for connecting the appliance to a standard AC or DC (Direct Current) power source. |
Grounding Post | For DC installations, you securely connect a grounding wire to the chassis and to earth ground, which typically is the equipment rack on which you install the appliance. The mounting nut is placed on the grounding post for convenience. Remove the mounting nut, place the grounding wire connector onto the grounding post and replace the mounting nut. Ensure that it is snug. |
Power LED | The power indicator is green if the power supply has power and is dark if it does not have power. |
Air Vent | An air vent that allows warm air to flow out of the appliance. Do not obstruct. |