vNIOS for KVM supports most of the features of the Infoblox NIOS appliances, with the following limitations:

...

  • If the vNIOS instance fails to launch, the ports created for the instance are not deleted automatically. You need to delete them manually.
  • When you start an FTP connection on OpenStack with the Listen on port field set to 2021, you need to manually add a rule to allow the 2021 port. This ensures that the connection is successful.
  • Connection to the FTP service might fail when the virtual appliance enter the passive mode. To avoid this, do the following:
    • Use active mode instead of passive mode.
    • Modify the vnios-sec-group security group to open ports 1023 and above.
    • Use the FTP client inside the internal network.
  • The vNIOS instances deployed in the OpenStack environment do not support HSM Safenet groups.
  • IPv6 support in the OpenStack environment is limited by the Juno release and has not been verified by Infoblox.
  • You cannot configure the reporting virtual appliance as an HA pair. You also cannot configure it as a Grid Master or Grid Master Candidate. You can use it only as a dedicated reporting server in the Grid.
  • At certain times, a power failure (or an unexpected reboot) of the VM host may cause VM guest corruption unless writes are correctly persisted.  To do this, you must have an NVRAM-based disk controller on the host system and turn-off guest disk caching. That is, you must set the disk_cachemodes parameter to the writethrough value. The method to set the disk_cachemodes parameter varies for different hypervisors. 
    The following example pertains to vNIOS for KVM deployed in OpenStack 16.2. :
    • Log in to the system as a root user.
    • Edit the edit nova.conf and nova-cpu.conf files by running the vim /etc/nova/nova.conf and vim /etc/nova/nova-cpu.conf commands.
    • Go to the [libvirt] section in both the files.
    • On a new line, add disk_cachemodes="writethrough".
    • Restart the nova services.
    The following example pertains to vNIOS for KVM Hypervisor through the KVM Manager:
    • In KVM virt-manager, select writethrough from the disk cachemode drop-down list when deploying the instance.
    • Validate the instance by editing the guest XML file and updating the cache parameter inside the driver tag to specify a caching option to configure the cache mode. For example, to set the cache parameter to writethrough
      <disk type='file' device='disk'>
      <driver name='qemu' type='qcow2' cache='writethrough'/>
      <source file='/home/vms/mygm.qcow2' index='1'/>
      <backingStore/>
      <target dev='vda' bus='virtio'/>
      <alias name='virtio-disk0'/>
      ><address type='pci' domain='0x0000' bus='0x07' slot='0x00' function='0x0'/>
      </disk>