RAID 10 (or sometimes called RAID 1+0) uses a minimum of four disk drives to create a RAID 0 array from two RAID 1 arrays, as shown in Figure 8.15. It uses mirroring and striping to form a stripe of mirrored subsets. This means that the array combines—or stripes—multiple disk drives, creating a single logical volume (RAID 0). RAID 10 combines the high performance of RAID 0 and the high fault tolerance of RAID 1. Striping disk drives improves database write performance over a single disk drive for large databases. The disks are also mirrored (RAID 1), so that each disk in the logical volume is fully redundant.

Anchor
bookmark1016
bookmark1016
Figure 8.15 RAID 10 Array Configuration<place for figure>

Drawio
bordertrue
viewerToolbartrue
fitWindowfalse
diagramName8.15
simpleViewerfalse
width
revision1


When evaluating a fault on the Infoblox-4010, it is best to think of the disk subsystem as a single, integrated unit with four components, rather than four independent disk drives. For information, see Evaluating the Status of the Disk Subsystem.

...

The disk drives of the Infoblox-4010 are located on the appliance front panel. To the right of each drive, two LEDs display connection and activity status. Table 8.10 lists the disk drive LED combinations and the states they represent.

Anchor
bookmark1019
bookmark1019
Table 8.10 Infoblox-4010 Disk Drive LED Combinations

Online/Activity LED (Green)Fault/UID LED (Amber/Blue)Description
On, off, or blinkingAlternating amber and blueThe drive has failed, or it has received a predictive failure

alert; it also has been selected by a management application.

On, off, or blinkingSteadily blueThe drive is operating normally.
OnAmber, blinking regularly (1 Hz)The drive has received a predictive failure alert. Replace the drive as soon as possible.
OnOff The drive is online but it is not currently active.
Blinking regularly (1Hz)OffDo not remove the drive. The drive is rebuilding. Removing the drive may terminate the current operation and cause data loss.
Blinking irregularlyAmber, blinking regularly
(1 Hz)
The drive is active, but it has received a predictive failure alert. Replace the drive as soon as possible.
Blinking irregularlyOffThe drive is active and operating normally.
OffSteadily amberA critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible.
OffAmber, blinking regularly
(1 Hz)
The drive has received a predictive failure alert. Replace the drive as soon as possible.
OffOffThe drive is offline, a spare, or not configured as part of an array.