Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Reverted from v. 9

...

vNIOS ApplianceOverall Disk (GB) of vCPU Cores Memory Allocation (GB)Virtual Machine SizeSupported as Grid Master and Grid Master Candidate
TE-V825 *250214

DS11_V2 Standard

Yes
TE-V1425 *250428DS12_V2 StandardYes
TE-V2225 *250856DS13_V2 StandardYes
CP-V80016027

DS2 Standard or DS2_V2 Standard

No
CP-V1400160414DS3 Standard or DS3_V2 StandardNo
CP-V2200160414DS3 Standard or DS3_V2 StandardNo

The following table lists the vNIOS for Azure appliance models that are supported for NIOS 8.4.0 and later releases.

vNIOS ApplianceOverall Disk (GB) of vCPU Cores MemoryAllocation (GB)Virtual Machine SizeSupported as Grid Master and Grid Master Candidate

CP-V805 *2

250

2

16

DS11_V2 Standard

No

CP-V1405 *2

250

4

32

DS12_V2 Standard

No

CP-V2205 *2

250

8

64

DS13_V2 Standard

No

...

Note: * Trinzic vNIOS appliances (TE-V825, TE-V1425, TE-V2225) for Azure do not support downgrading from NIOS 8.2.x to any earlier NIOS releases. After you successfully install a vNIOS for Azure instance, you may upgrade to a supported NIOS software release on the instance. The vNIOS for Azure is supported starting with NIOS 8.0.0; therefore, downgrading to an earlier NIOS 8.0.0 version will fail. If for any reason your upgrade fails, you can review the Infoblox syslog to find out the reasons for the failure. For information about how to access the syslog, refer to the Infoblox NIOS Administrator Guide.
         *2 CP-V805, CP-V1405, and CP-V2205 do not support downgrading from NIOS 8.4.x to any earlier NIOS releases and is only supported in NIOS 8.4 and later releases.

...