NetMRI discovery depends on a collection of under-the-hood features to ensure that polling and addition of devices in the network proceed smoothly and accurately. This chapter describes three critical tasks:
...
- Script Execution: If enabled, Configuration Command Scripts or Perl scripts can be executed by NetMRI users with the correct privileges.
- Vendor Default Credential Collection: If enabled, NetMRI will automatically check for default vendor credentials at the interval specified in Frequency (Daily or Weekly). Checking for vendor default credentials ensures that the network meets compliance standards.
...
Note: The topics under Configuration Management provide more information about configuration collection and related operations.
...
Configuring IPAM Sync
To add a sync configuration, do the following:
...
- Network sync: Newly-imported subnets are imported as “managed”.
- If the imported subnet conflicts with an existing subnet, it is not accepted. The imported subnet can go into a container as long as there is no conflict.
- If the subnet already exists, no changes are made.
- If the subnet is in IPAM but not in NetMRI, it is left in IPAM.
- IP address sync: New IP addresses are added and marked as “unmanaged”. If an IP address already exists, the field values is overwritten during the import.
- Before NetMRI 7.1.4 and NIOS 8.1: If the IP address exists in IPAM but it is not in the import file, it is left in IPAM.
- As of NetMRI 7.1.4 and NIOS 8.1: If the IP address exists in IPAM but it is not in the import file, its discovered data is cleared out. You can control the time that the IP address stays in the NetMRI database after it is no longer discovered under NetMRI. To do so, go to Setup -> General Settings -> Advanced Settings.
Delivering NetMRI Discovered Data to IPAM
Fields related to Cisco ACI data (tenant, bridge_domain, endpoint_groups) are specific for SND elements and controllers. Fields Wireless Access Point Name, IP, and SSID are related to the wireless access points to which a device is connected. Attached device information usually means neighbor switch or router to which a given device is directly connected. Only IP Address, MAC Address, Last Discovered, and First Discovered fields are filled for end hosts collected from ARP tables. VRF information is specified for corresponding interfaces of infrastructure devices.
...
Anchor | ||||
---|---|---|---|---|
|
Anchor | ||||
---|---|---|---|---|
|
NetMRI automatically supports an Infoblox utility, Cisco Discovery Service, that enables network administrators to provide Cisco-validated reporting and analysis. NetMRI operates as a Cisco Discovery Service-enabled system supporting discovery of network systems for analysis and management. You can use the CDS Integration Tool as part of a new NetMRI installation, or use the tool to extract further insight and value from an existing deployment. Cisco Gold Partner status is required for effective use of the software utility.
NetMRI supports CDS API version 2.0 and uses a NetMRI device or virtual machine to inspect all aspects of a network's Cisco infrastructure to collect the following information:
...