Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Identify and verify the failed drive through the Grid Manager or the CLI.

  2. Press the release button to release the catch-release lever.

  3. Use the catch-release lever to pull the disk about two cm (one inch) to disengage contact, as indicated in the figure below.

  4. Wait about 30 seconds for the drive to completely stop spinning.

  5. Remove the drive, extract it from its carrier and handle it with care. Do not drop the drive or ship it loosely in a carton.

  6. Securely mount the replacement drive in the drive carrier and replace the carrier in the system.

  7. Push the lever down to lock the drive in place.
    The LED next to the drive lights up.

  8. The drive automatically goes into rebuilds mode.

Note

Note

...

IP settings and basic network configurations, such as the gateway address, netmask, Grid secret and Grid name, are saved and restored when you replace a failed drive.

Notes on Drive Replacement

...