Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • set dns transfer–Schedules zone transfers. Note that set dns transfer is not used by IB-4030 or IB-4030-10GE with an active DNS Cache Acceleration license.
  • set monitor dns –Activates DNS monitoring in NIOS. This command is disabled on IB-4030 or IB-4030-10GE with an active DNS Cache Acceleration license.
  • show monitor dns –Displays DNS network monitoring data. This command is disabled on IB-4030 or IB-4030-10GE with an active DNS Cache Acceleration license.
  • set interface–Defines port speed and duplex settings for all supported interfaces.
  • show interface–Shows the status and configuration of a chosen port.
  • show smartnicshow dns accel–Shows the cusrrent status of the appliance. This command applies only to IB-4030 or IB-4030-10GE appliances.
  • show smartnicdns accel-cache–You can view the current accelerator cache contents or view the prior cache dump file. This command may affect DNS query response performance for around 15 seconds during execution. This command applies only to IB-4030 and IB-4030-10GE appliances with DNS cache acceleration license enabled.
  • set smartnic set dns accel log–Specify the log level for the DNS Cache Acceleration service on the appliance.
  • set temp_license–Generates and installs a temporary DNS cache acceleration license. You can add a temporary DNS cache acceleration license for up to one million qps. Note that you cannot add a temporary license if a permanent license already exists.
  • show license–Displays the capacity of the applicable DNS cache acceleration license type.
  • show smartnicdns accel-cache existing-file–Displays the existing cache data file of IB-4030 and IB-4030-10GE.

The CLI commands listed below are frequently used on the appliance. For detailed information about the supported CLI commands, refer to the Infoblox CLI Guide.

...

set dns

The set dns command enables you to control the DNS cache. You can flush the cache of a DNS view or flush a particular entry from the cache.

...

Infoblox > set dns flush name accounting.corp100.com
Infoblox > set dns flush all

...

show dns

The show dns command displays DNS query statistics for all DNS views in the IB-4030 or IB-4030-10GE appliance. It also displays the recursive cache for the specified DNS views.

...

Infoblox > show dns stats
success 6718810
referral 0
nxrrset 0
nxdomain 0
recursion 257
failure 0

...

set dns accel log

Sets the logging level for the DNS Cache Acceleration service on the IB-4030 or IB-4030-10GE appliance, where the level is between 0 being the least verbose and 7 being the most verbose.

Syntax

set smartnic set dns accel log {level]

Argument Description
level The logging level (from 0 to 7) of messages.

Example

Infoblox > set smartnic set dns accel log 7

...

show dns accel

Checks the status and settings of the DNS Cache Acceleration service.

Note
titleNote

...

When you use this command on a specific appliance, the configuration applies only to that appliance. When using this command for an HA pair, you must run the command separately on both the active and passive nodes to ensure consistent behavior.


Show smartnic Show dns accel displays the following operating characteristics of the IB-4030 or IB-4030-10GE:

  • Firmware version
  • DNS query statistics
  • Cache status, enabled/disabled
  • DNS per-port packet count
  • Cache hit count
  • Log level
  • Cache miss count
  • Failed cores (if any)
  • DNS minimum cached TTL

Syntax

show smartnicshow dns accel

Example

Infoblox > show smartnicdns accel
Firmware version:     1.3.19, Nov 08, 2011
Cache:                Enabled

Cache hit count:      109397
Cache miss count:     3008
Minimum cached TTL:   10

DNS query stats:      SUCCESS=109380 NXDOMAIN=0 NXRRSET=0 FAILURE=0 REFERRAL=0
DNS UDP packet count: port0=299339 port1=93408 port2=0 port3=0
Log level:            6

Failed cores:         None

...

This command displays details about interfaces and SFPs that are connected to the IB-4030 or IB-4030-10GE platform.

Syntax

show interface

Example

Infoblox > show interface

LAN:
IP Address: 10.35.2.40    MAC Address:  00:0F:B7:24:10:15
Mask:       255.255.0.0   Broadcast:    10.35.255.255
MTU:        1500          Metric:       1
IPv6 Address: 2001:db8:a23::228/64
IPv6 Link: fe80::20f:b7ff:fe24:1015/64
Status: UP BROADCAST RUNNING MULTICAST
SFP Type: Fiber SX
SFP Model: Finisar(FTLF8519P2BCL)
Statistics Information

Received

packets:  6895339    bytes:   444006210 (423.4 MiB)
errors:   0          dropped: 14
overruns: 0          frame:   0

Transmitted

packets:  14832      bytes:   14599721 (13.9 MiB)
errors:   0          dropped: 0
overruns: 0          carrier: 0

Collisions: 0               Txqueuelen: 1000


You can view information about the SFPs on the IB-4030 or IB-4030-10GE application. To view the details:
From the Grid tab, select the Grid Manager tab and click the Members tab -> member check box -> Detailed Status icon.
You can also use this command to view the VLAN ID, tagged networks, and additional IP addresses that are configured for the network when you enable VLAN on an IB-4030 or IB-4030-10GE appliance. For more information, see Enabling VLAN Support Using CLI Commands.