The Infoblox 1405 Series platforms are 1-U appliances that you can efficiently mount in a standard equipment rack. For rack mounting information, see see Rack Mounting Procedures.

...

.

Appliance Front Panel

The front panel components include the LCD (liquid crystal display) panel and navigation buttons, communication ports, and LEDs, as shown in Figure 1 and described in Table1. For explanations of Ethernet port LEDs, and console and Ethernet port connector pin assignments, see Ethernet Port Ethernet Port LEDs and DB-9 Console Console Port and and RJ-45 Port 45 Port Pinouts.
Anchorbookmark7
bookmark7Figure 1 Infoblox 1405 Series, Front View

...


The front panel components are described in Table1.
anchor
bookmark8bookmark8Table 1 Front Panel Components

Component

Description

Hard Disk Drive(s)

The Trinzic TE-1415 and TE-1425 appliances, and Advanced Appliance PT-1405 each provide one (1) Infoblox hard disk storage device.
The Trinzic Reporting TR-1405 appliance, and Network Insight ND-1405 appliance provides two (2) hard disks in a RAID 1 array. Each disk drive has LEDs on the far left side of each drive carrier, that indicate the connection and activity status on the disk drive. The top LED flickers to blue when the disk drive is operational and performing read-write operations. The lower LED is dark (inactive) during all operations. Both drive LEDs are dark when the disk drive is not connected. You must use the Grid Manager UI or the NIOS CLI to verify disk operation. For more information, see Evaluating the Status of the Disk Subsystem.

On/Off Switch

A power switch to turn the power supply of the appliance on and off. The switch is hidden. Use a small blunt object, such as a paper clip, to gently push the switch.

Power LED

An LED that glows blue when there is power to the appliance. When it is dark, the appliance is not receiving power, even if the power cable is plugged in. When it glows red, there is an error. Ensure that you power on the appliance through the On/Off switch using a small blunt object, such as a paper clip.

IPMI Port

Dedicated Ethernet port used for LOM (Lights Out Management) with specific releases of NIOS. The IPMI/LOM Port supports 10/100/1000 Mbps operations. Ensure that the IPMI port is properly connected to the network before you configure LOM through Grid Manager for remote management. The IPMI port auto-negotiates up to Fast Ethernet 1000BASE-TX speeds; ensure that the switch port to which the IPMI port connects will auto-negotiate to 1000 Mbps operation.

USB Port

Reserved for future use.

Console Port

A male DB-9 serial port for a console connection to change basic configuration settings and view basic system functions through the CLI (command line interface).
If your system lacks a DB-9 serial port, use a properly grounded USB-to-Serial dongle for connection to the serial console port. If the dongle is connected to a laptop, the laptop also must be properly grounded. Failure to do so may cause damage to the serial console port of the Infoblox appliance. Infoblox is not responsible for such damage. For DB-9 pin assignments, see Figure 4.

MGMT Port

A 10/100/1000-Mbps gigabit Ethernet port that you can use for appliance management or DNS service. You can enable the MGMT port and define its use through the Grid Manager after the initial setup.
The Advanced Appliance PT-1405 must be managed through its MGMT port.

HA Port (Active for high availability in the TE-1415 appliances and PT-1405)

A 10/100/1000-Mbps gigabit Ethernet port through which the active node in an HA (high availability) pair connects to the network using a VIP (virtual IP) address. HA pair nodes also use their HA ports for VRRP (Virtual Router Redundancy Protocol) advertisements. From NIOS 8.6.x onwards, hybrid HA is supported. A hybrid HA pair can comprise a physical appliance and a virtual appliance, two physical appliances, or two virtual appliances. For more information on limitations of using HA pair combinations, see Limitations of Using a Combination of a Physical Appliance and a Virtual Appliance for HA.
ND-1405 and TR-1405 Reporting: The HA Port is inactive and reserved for future use.

LAN1 Port

A 10/100/1000-Mbps gigabit Ethernet port that connects the appliance to the network. You must use the LAN1 port to set up the appliance initially. It handles all traffic if you do not enable the MGMT and LAN2 ports. The passive node in an HA pair uses this port to synchronize the database with the active node.

LAN2 Port

A 10/100/1000-Mbps gigabit Ethernet port that connects the appliance to the network. The LAN2 port is disabled by default. You can enable the LAN2 port and define its use through the Grid Manager after the initial setup.

UID Button

The unit identification button. When you press the UID button, the UID LED on the front and rear panel glows blue. In a rack environment, the UID feature enables easier location of a server when moving between the front and rear of the rack. You can also identify the appliance through the Grid Manager and CLI commands.

CPU and RAMInfoblox 1405 Series appliances include 8 CPUs 3.6GHz with 32GB RAM.

CC and FIPS Compliance for 1405 Series Appliances

The Trinzic 1405 series appliances can be made compliant with CC and FIPS 140-2 security standards. For the list of Trinzic appliances that can be made CC and FIPS compliant, see the Common Criteria and FIPS Compliant Appliances section in the the Infoblox NIOS 8.5 Documentation. Both CC and FIPS give assurance that the product satisfies a set of internationally recognized security measures. CC is a set of rules and specifications to evaluate the security of Information Technology (IT) products. FIPS is a U.S government computer security standard that is designed to validate product modules that use cryptography. This is necessary to maintain the integrity and confidentiality of the end-user information that is stored, processed, and transferred by the product module. To ensure that your appliance is CC and FIPS compliant, make sure that your hardware and software settings match the evaluated configuration that was certified for both CC and FIPS. For information about how to configure CC and FIPS, refer to the Infoblox NIOS Administrator Guide.

...

Clean the chassis before affixing tamper evident FIPS labels. Apply these labels as shown in the figures below:

FIPS label

Image RemovedImage Added

Install a sticker on the drive bay cover as shown in the picture

Drawio
border1
baseUrlhttps://infoblox-docs.atlassian.net/wiki
diagramName1405_DriveBay
width400
zoom1
custContentId7080434
pageId13566058
custContentId7080434
lbox1
contentVer1
revision2

...

Install a sticker covering the IPMI port as shown in this picture

...

Ethernet Port LEDs

...

View the Activity and Link LEDs to see link activity and connection speeds on Ethernet ports. Figure 2 describes the status conveyed by Ethernet port LEDs through their color and illumination (steady glow or blinking).

...


...

Figure 2 Ethernet Port LEDs (inc. SFP+ interfaces where noted)

Image Modified

...

SFP/SFP+ Interface Support

All models in the Infoblox 1405 Series support optional interface configurations to accept SFP transceiver modules, for 1GbE optical connectivity.
To support connectivity to 10 Gigabit networking infrastructure, Infoblox also offers versions of the TE-1415, TE-1425, Network Insight ND-1405 and Trinzic Reporting TR-1405 that provide 10-Gigabit Ethernet (10GbE) interfaces accepting SFP+ transceiver modules for 10GbE RJ-45 copper or optical network connectivity. Figure 3 shows an Infoblox 1405 Series appliance with optical interfaces.
Table 2 summarizes SFP and SFP+ support for appliance models in the Infoblox 1405 Series.

...

Note
titleNote

You cannot add SFP/SFP+ support after you have purchased an appliance model that does not have the SFP/SFP+ interfaces pre-installed. Contact your Infoblox representatives if you are interested in purchasing appliances that support SFP/SFP+ interfaces.

...


Figure 3 Infoblox 1405 Series, Front View with Four SFP/SFP+ Interfaces
 

...


In optional configurations for select Infoblox 1405 Series appliances, 1GbE SFP and 10GbE SFP+ ports replace the functionality in the original built-in MGMT, LAN1, HA and LAN2 ports, thereby disabling the built-in ports as indicated in Figure3. 10GbE support accepts Infoblox-provided SFP+ 10GbE Short Range and Long Range transceivers, Cisco SFP+ Direct Attach 10GSFP+Cu, or HP HPJ9283B SFP+ Direct Attach 10GSFP+Cu transceivers.
You may mix media types in the set of ports (e.g., two copper interfaces and two fiber interfaces).
You may use SFP and SFP+ transceivers in a mixed configuration in 4-Port 10GbE appliances. An example use case involves installing 10GbE SR SFP+ transceivers in the LAN1 and LAN2 ports for the TE- 1415 or TE-1425 appliance, and installing 1GbE SFP copper transceivers in the MGMT and HA interfaces.

Note
titleNote

For ND-1405 and TR-1405 appliance models configured with 1GbE SFP or 10GbE SFP+ interfaces, the HA port is reserved for future use and cannot be used for network applications. Order of ports from left to right is otherwise the same. (The PT-1405 does not support 10GbE operation, but supports HA.)

...


Table 2 SFP/SFP+ Appliance Support Summary

...

  • IB-SFPPLUS-LR
  • IB-SFPPLUS-SR
  • IB-SFP-SX
  • IB-SFP-CO
  • Finisar FTLF1318P3BTL
  • Cisco SFP-H10GB-CU5M
  • HPJ9283B

...

Interface Connector Pin Assignments

An Infoblox appliance has three types of ports on its front panel:

...

Figure 4 describes DB-9 and RJ-45 connector pin assignments. The DB-9 pin assignments follow the EIA232 standard. To make a serial connection from your management system to the console port, you can use an RJ-45 rollover cable and two female RJ-45-to-female DB-9 adapters, or a female DB-9-to-female DB-9 null modem cable. The RJ-45 pin assignments follow IEEE 802.3 specifications. All Infoblox Ethernet ports are auto-sensing and automatically adjust to standard straight-through and cross-over Ethernet cables.
Anchorbookmark15bookmark15
Figure 4 DB-9 Console Port and RJ-45 Port Pinouts



...


...

TE-1415, TE-1425, PT-1405, and ND-1405 Appliance Rear Panel

Infoblox 1405 Series rear panel components include the power connectors, hard disk drive, fans, and the UID LED, as shown in Figure 5. Anchorbookmark f5bookmark f5

Figure 5 Infoblox 1405 Series, Rear View

...