About Automatic Failover
About Automatic Failover
Anchor
bookmark82
bookmark82
You can create a NetMRI failover pair using two NetMRI appliances, in which one acts as the primary appliance and the other as the secondary appliance. A failover pair provides a backup or redundant operational mode between the primary and secondary appliances so you can greatly reduce service downtime when one of them is out of service. You can configure two Operation Center (OC) appliances, collector appliances, or standalone appliances to form a failover pair.

...

Note the following about the automatic failover feature:

  • Failover A failover pair is supported only on NetMRI NT-1400, NT-2200, and NT-4000 (G8-only) appliances. 
  • A failover pair is supported on virtual NetMRI virtual appliances in NetMRI 7.5.4 and later releases.
  • Failover is supported in NetMRI 7.1.1 and later releases.
  • Collector failover is supported in NetMRI 7.1.2 and later releases.
  • Both the The primary and secondary appliances must be of have the same appliance model and same software version numberhardware models or VM configurations and software versions.
  • The management IP address of both the primary and secondary appliances must be on the same subnet.