Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Drawio
custContentId
border1
baseUrlhttps://infoblox-docs.atlassian.net/wiki
diagramName12
width2381
zoom1
custContentId7342679
pageId13434921
7342679lbox1
contentVer1
revision1

...

By default, an Infoblox appliance automatically negotiates the optimal connection speed and transmission type (full or half duplex) on the physical links between its LAN1, LAN2, HA, and MGMT ports and the Ethernet ports on a connecting switch.
Occasionally, the appliances may fail to auto-negotiate that speed and type, and instead connect at lower speeds of either 100 or 10 Mbps using potentially mismatched full- and half-duplex transmissions. If this occurs, begin by determining whether there is a firmware upgrade available for the switch. If so, apply the firmware upgrade to the switch and test the connection. If that does not resolve the issue, manually set the ports on the Infoblox appliance and on the switch to make 1000-Mbps full-duplex connections. Refer to the section Modifying Ethernet Port Settings in  in the Infoblox NIOS Administrator Guide for the steps to resolve the problem.

...

Use the Infoblox Grid Manager to access the Infoblox appliance from a management system. Through the Grid Manager, you can set up and administer the appliance. For management system requirements and access instructions, see Accessing the Infoblox 805 Series Appliance.