The Infoblox TE-1506 appliance ships with one solid-state drive (SSD). When you replace a failed solid-state drive, you must replace it with an Infoblox supplied solid-state drive. To ensure that you receive the correct replacement drive, report the drive type or part number of the failed drive. The appliance also displays the drive type in the Detailed Status panel of the Grid Manager.
Note |
---|
Note TE-1506 has two solid-state drive slots, but only one of them is active. The second slot is a non-functional SSD slot. |
- Caution: Installing drives that are not qualified and shipped from Infoblox could cause failures in the appliance.
...
- Caution: Never remove a correctly functioning drive in a live system.
To remove the disk solid-state drive:
Identify and verify the failed drive through the Grid Manager or the CLI.
Press the release button to release the catch-release lever.
Use the catch-release lever to pull the disk about two cm (one inch) to disengage contact, as indicated in the figure below.
Remove the drive, extract it from its carrier and handle it with care. Do not drop the drive or ship it loosely in a carton.
Securely mount the replacement drive in the drive carrier and replace the carrier in the system.
Push the lever down to lock the drive in place.
The LED next to the drive lights up.The drive automatically goes into rebuilds mode.
...