Following are the pre-requisites for deploying automatic failover for new appliances:

  • Configure two supported NetMRI appliances with licenses installed.

  • Both the appliances must be of the same appliance model and same software version number.

  • By default, two network adapters are configured without HA:

    • Management Interface

    • Scan Interface

  • When VM HA needs to be enabled, a third interface is required:

    • HA Provisioning Interface

  • Provision three IP addresses on the same subnet: a VIP address and two management IP addresses for the appliances.

  • If you use the direct replication method to connect two appliances, you need an Ethernet cable to connect the appliances directly through their HA ports. This is applicable only to hardware appliances.

  • If you are using the network replication method to connect the appliances, you must connect the systems over a local network and two replication IP addresses must be acquired on the same subnet. You must also select a TCP port for the replication traffic.

Note

Infoblox recommends using the direct replication method for best reliability and performance. The network replication method will have higher latency and a greater chance of connection breakage, and thus lower reliability and performance.

To deploy two new Operation Centers or standalone appliances to form a failover pair, do the following:

  1. Set up and configure two new NetMRI appliances.
    Note that Infoblox recommends setting up virtual machines (data center or hypervisor) in the same location. If the machines are not set up in the same location, high latency or limited bandwidth can cause unstable performance.
    Infoblox recommends that you connect the systems using the direct replication method.

  2. Run the Setup Wizard on both appliances and set the admin password and install the license. The admin password and time settings must be the same on both systems. For information, see the Running the Setup Wizard topic and its subsections in the NetMRI online Help. At this point in time, it is not necessary to complete the entire configuration wizard on both systems. You can complete the configuration only on the primary system.

  3. For new systems with no network device data collected, you can proceed without resetting and without generating a backup. For systems that are already deployed, and have collected data, follow the steps mentioned in Migrating Existing Systems as Failover Pairs.

  4. Choose one system to take the primary role. You can choose the system for which you have completed the entire configuration. Otherwise, the configuration might be lost.

  5. To log in to the primary system, click the Settings icon > Setup > Failover Configuration and then specify the configuration settings on in the Failover Configuration page. On both nodes, the replication IP and replication subnet configurations must be set to the same network. For more information, see the Specifying Automatic Failover Settings topic in the NetMRI online Help.

Note

After specifying the failover configuration settings and completing the enable operation, the systems start synchronizing data. This process might take up to one hour, depending on the appliance model.