The Interface Live Viewer allows you to view and track traffic and event trends for any chosen network interface, and save chart data and images for the results. the Interface Live Viewer displays near-real-time graphs for the following interface properties:
Throughput/Utilization graphs depend on the Display Mode setting: choosing Rate displays throughput, choosing Percent displays utilization.
To access the Interface Live Viewer, do the following:
1. Right-click any interface hyperlink, then click Interface Live Viewer in the pop-up menu.
–or– In the Interface Viewer, click the Viewer Tools icon, then click Live Viewer... in the drop-down menu.
–or– In the Interface Viewer –> Performance section –> Charts page (which displays static data), click the Live Viewer link next to the Measure field.
Within the graph:
If too many lines make it difficult to interpret the graph, hide lines having less value by clicking the colored check- box for any data type at the bottom of the chart window.
To hide or show data callouts within the graph, do the following: In the graph, click the line for which you want to hide/show data. Or:
In the legend, click the name (underlined = data callout displayed, name not underlined = data callout hidden). In the Interface Live Viewer's control bar (above the graph):
The display window of 5 or 15 minutes is based on an ideal polling frequency as defined in the Live Interface Poll Frequency setting (at Settings icon –> General Settings –> Advanced Settings). The display window depends on the following factors: load on the device being polled, load on the appliance polling the device, and network round trip time between the device and NetMRI. Thus, the actual display window time may be longer than the value selected in the Display Window drop-down list.
Note: If the display remains paused after 24 hours, data collection will stop.
154Infoblox NetMRI Administrator GuideRelease 7.2.1
Using the Interface Live Viewer
Two settings for the Interface Live Viewer are provided in the Settings icon –> General Settings –> Advanced Settings page under Data Collection:
The polling engine continues to run for 15 cycles (where one cycle = Live Interface Poll Frequency) after the Interface Live Viewer window is closed. If you reopen the Interface Live Viewer before the 16th cycle, you'll see live data collected during that time. If reopened after the 15th cycle, the Interface Live Viewer will start displaying a fresh data set.
!worddav82aac1426f41e4bf41b080762501fdd1.png|height=20,width=11!Release 7.2.1 Infoblox NetMRI Administrator Guide155
Introducing Network Explorer
!worddav82aac1426f41e4bf41b080762501fdd1.png|height=20,width=11!156Infoblox NetMRI Administrator GuideRelease 7.2.1