Enabling the discovery of Cisco Viptela devices provides visibility into your Cisco Viptela infrastructure. This allows you to view and manage discovered IP addresses of Cisco Viptela fabric members such as controllers and fabric switches with their attached end points. You can discover Cisco Viptela on-premise devices as well as cloud devices.

By default, Cisco Viptela discovery collects both connected and offline devices.

To add and configure a Cisco Viptela fabric discovery, complete the following:

  1. To enable SDN and SD-WAN polling, click the Settings icon > Setup > SDN/SD-WAN Polling. For more information, see Configuring SDN and SD-WAN Polling Settings.
  2. Click the Settings icon > Setup > Discovery Settings > SDN.
  3. Click New.
  4. In SDN Type, select Cisco Viptela.
  5. Complete the following:
    • Fabric Name: Specify a short and unique name for the current Cisco Viptela configuration.
    • Address: Specify the hostname or IP address of the Viptela vManage controller.
    • Network View: Select the network view to identify the corresponding network interface for connectivity with the Cisco Viptela.
    • Network Interface: Select the required network interface.
    • Protocol: The default selection is HTTPS.
    • On-premise controllerCheck this if your Viptela setup is on-premises.
    • CA Certificate: Specify a Root CA or Intermediate CA certificate to allow communication with the Cisco Viptela vManage controller. Do one of the following:
      • Select a previously imported CA certificate. To learn how to import a CA certificate in NetMRI, see Installing CA Certificate.
      • Click Import CA Certificate and select a CA certificate directly from your machine.
    • Username: The login name for the Cisco Viptela vManage controller.
    • Password: The login password.
    • (Optional) Maximum Requests per Second: Specify the maximum number of HTTP requests from NetMRI to Cisco Viptela SDN per second to avoid overload.
    • (Optional) Enable Discovery Blackout: Select the checkbox and then click its Scheduling icon. For more information, see Defining Blackout Periods.
  6. Click Test Connection to check if the fabric is reachable and the provided credentials are correct. The connection test results are also written to the Syslog.
  7. Click Add or Add & Discover.
  • No labels