Changing DC Power Supplies
Changing DC Power Supplies
In their DC power configuration, the Infoblox-4010 and Network Insight ND-4000 ship with two redundant, auto-switching DC power supplies. The power supplies are "hot-swappable", so you can remove or replace one power supply without interrupting appliance operation and network services.
To replace an Infoblox-4010/Network Insight ND-4000 DC power supply, do the following:
- Disconnect the DC power cable from the power outlet on the external transformer.
- Disconnect the power cable from the power supply.
- Gently push back the red catch-release lever, grip the power supply handle, and pull the power supply unit out of the chassis.
- Place the replacement power supply into the bay and push it forward until it is fully seated in the chassis. The red catch-release lever will gently click into place.
- Reconnect the power cable. If the power supply is fully seated and operating properly, the LED glows steady green.
Figure 24 Removing an Infoblox-4010 Rev-1 DC Power Supply
Figure 25 Removing an Infoblox-4010 Rev-2/Network Insight ND-4000 DC Power Supply