In their DC power configuration, the Infoblox-4010 and Network Insight ND-4000 ship with two redundant, auto-switching DC power supplies. The power supplies are "hot-swappable", so you can remove or replace one power supply without interrupting appliance operation and network services.
To replace an Infoblox-4010/Network Insight ND-4000 DC power supply, do the following:

  1. Disconnect the DC power cable from the power outlet on the external transformer.
  2. Disconnect the power cable from the power supply.
  3. Gently push back the red catch-release lever, grip the power supply handle, and pull the power supply unit out of the chassis.
  4. Place the replacement power supply into the bay and push it forward until it is fully seated in the chassis. The red catch-release lever will gently click into place.

  5. Reconnect the power cable. If the power supply is fully seated and operating properly, the LED glows steady green.


Figure 24 Removing an Infoblox-4010 Rev-1 DC Power Supply











Handle
Catch-release lever (Red)
Figure 25 Removing an Infoblox-4010 Rev-2/Network Insight ND-4000 DC Power Supply







HandleCatch-release
_lever (Red)_Ground Lug Nut