Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

The set lines command specifies the number of lines that the appliance displays when you execute a show command during a session. The default is 20 lines. You can also configure permanent page settings or enter zero (0) to set paging off.

Syntax

set lines [num | permanent]

ArgumentDescription
num The number of lines the appliance displays when you execute a show command.
permanent Configures permanent page settings.

Examples

Set the number of lines displayed on each page to 4:

Infoblox > set lines 4
Number of scroll lines set to 4.
Infoblox >
show log
May 31 13:30:05 (none) syslog-ng[892]: syslog-ng version 1.6.11 starting
May 31 13:30:05 (none) kernel: Linux version 2.6.17.4 (root@build-aslan) (gcc version
3.2.1) #1 SMP Fri May 18 19:44:21 EDT 2013
May 31 13:30:05 (none) kernel: BIOS-provided physical RAM map:
May 31 13:30:05 (none) kernel: BIOS-e820: 0000000000000000 - 000000000009f800 (usable)

Enter <return> for next page or q<return> to go back to command line.

Turn paging off for this session:

Infoblox > set lines 0
Number of scroll lines set to 0.

Set a permanent line number:

Infoblox > set lines permanent 24
Number of scroll lines set to 24.