When necessary, you can reset the B1-212 appliance to the factory default using one of the following methods:
When you reset the appliance, all configurations and software/patch versions on the appliance will be reset to the factory default. |
To reset the B1-212 appliance using a USB flash drive, do the following:
Obtain a USB flash drive that supports FAT32 (for Windows) or EXT4 (for Linux) file system.
Add an empty file called “dofactoryreset” to the USB flash drive by doing one of the following:
For Linux, create a file called “dofactoryreset” in the root file system of the USB.
If you use a USB drive that contains a previously downloaded or created “dofactoryreset” file, ensure that you change the timestamp of the file before resetting your B1-212 appliance. Otherwise, you will not be able to reset the appliance. On a Linux system, you can use the "touch" command to change the timestamp of the file. You can also remove the old file and download a new one from the Infoblox Portal. |
To reset the B1-212 appliance using the Device UI, do the following:
In the Enable Local Access dialog, click Enable. Local access to the appliance is granted for two hours. Note that enabling local access to the B1-212 appliance allows you to reset the NIOS-X server using the Device UI.