Powering the Appliance
Powering the Appliance
The TE-1415, TE-1425, PT-1405 and ND-1405 appliances ship with one (1) AC power supply module or one DC power supply module. You can order an additional power supply to set up a redundant hot-swappable 1+1 configuration. In the 1+1 configuration, Infoblox recommends using the power cables that ship with the appliances to connect each power supply to separate power circuits. In the event of a power failure on one circuit, the appliances can then operate on the other circuit.
The Trinzic Reporting TR-1405 appliance provides a default 1+1 redundant power supply configuration.
Note: If your appliance comes with one power supply and an empty module, the single power supply must reside in the PSU #1 slot.
To power the appliance:
- Connect a power cable between the power connector on the back of the appliance and a properly grounded and rated power circuit that meets the provisions of the current edition of the National Electrical Code, or other wiring rules that apply to your location. Make sure that the outlet is near the appliance and is accessible.