Document toolboxDocument toolbox

Restricting Synchronization on Managed Grids

You can restrict synchronization of selected network views, network containers, networks, and extensible attributes by using the Disable Sync to MGM option on the Grid Masters of the managed Grids. You use this option to restrict certain networks and networking information by not sharing it with the Multi-Grid Master. In addition, you can prevent the Multi-Grid Master from having access to the snapshots of the managed Grids. When you disable synchronization, all synchronized data is deleted and future synchronization is disabled.


Note: The Disable Sync to MGM checkbox is available only on the managed Grid when it remains joined with the Multi-Grid Master.


When you disable synchronization on a parent object, the synchronization is restricted on all its child objects. You cannot override this setting (you cannot enable synchronization) on the child object. However, you can disable synchronization at the child object if you have not restricted (disable) synchronization at the parent level. For example, if you disable synchronization at the network view level, then the synchronization is disabled for all the network containers and networks that are added to this network view. You cannot override this settings and enable synchronization at the network level.
You can restrict synchronization on the following: