Changing DC Power Supplies
Changing DC Power Supplies
In DC power configurations, the Infoblox 4000 Series appliances ship with two redundant, hot-swappable, auto-switching DC power supplies.
To replace an Infoblox 4000 Series DC power supply, do the following:
- Disconnect the DC power cable from the power outlet on the external transformer.
- Disconnect the power cable from the power supply.
- Disconnect the ground cable lugs from the power supply.
- Gently push back the red catch-release lever, grip the power supply handle, and pull the power supply unit out of the chassis.
- Place the replacement power supply into the bay and push it forward until it is fully seated in the chassis. The red catch-release lever will gently click into place.
- Reconnect the power cable. If the power supply is fully seated and operating properly, the LED glows steady green.
Figure 16 Removing an Infoblox 4000 Series DC Power Supply
Notes on Changing AC Power to DC Power
Infoblox offers the ability to change an AC-equipped Infoblox 4000 Series appliance to use DC power supply units (PSUs) by ordering field-replaceable unit DC PSUs (listed in Table 10). Should you choose to swap out an appliance's AC power supplies to use DC power supplies, follow these key points:
- You cannot convert an AC-equipped Infoblox 4000 Series appliance to NEBS compliance by swapping out AC power supplies for DC power supplies. You are simply changing the power factor of the appliance.
- Ensure that you have proper ground connections that connect to the ground lug screws on each DC PSU. These lug screws will be marked with a standard electrical ground symbol on each DC PSU, as labeled in Figure 16.
- Your Infoblox 4000 Series appliance provides a ground lug, with two star washers and a ground lug screw, in the accessory kit bundled with your appliance. (This accessory is not used for AC power.) Ensure that this ground lug is properly installed with a grounding cable to chassis ground. For information, see Ground Lug Installation (DC Systems Only).
Important – Retain your original AC power supplies for possible future RMAs
- When you remove the AC power supplies for new DC power supplies, ensure that you keep the original AC power supplies in a safe place for use in RMA situations.
- For appliance RMAs, you must replace the DC power supplies in the appliance with its original AC power supplies before RMA shipment back to Infoblox.
- Keep your DC power supplies in your facility until you receive your replacement appliance.
Related content
Changing DC Power Supplies
Changing DC Power Supplies
More like this
Changing AC Power Supplies
Changing AC Power Supplies
More like this
Changing AC Power Supplies
Changing AC Power Supplies
More like this
Powering On the Infoblox 4000 Series Appliance
Powering On the Infoblox 4000 Series Appliance
More like this
Changing AC Power Supplies
Changing AC Power Supplies
More like this
Powering On the Appliance
Powering On the Appliance
More like this