When necessary, you can reset the B1-212 appliance to the factory default using one of the following methods:
- USB flash drive
- Device UI
Important
Resetting via a USB Flash Drive
To reset the B1-212 appliance using a USB flash drive, do the following:
- Insert the USB flash drive into the USB port of the B1-212 appliance.
Obtain a USB flash drive that supports FAT32 (for Windows) or EXT4 (for Linux) file system.
Add an empty file called “dofactoryreset” to the USB flash drive by doing one of the following:
- From the Infoblox Portal, download the “dofactoryreset” file to the USB by clicking Configure > Administration -> Downloads -> Download Factory Reset.
For Linux, create a file called “dofactoryreset” in the root file system of the USB.
- Insert the USB flash drive into the USB port of the B1-212 appliance.
- The appliance detects the settings on the USB flash drive and begins performing the factory reset operation.
- During the reset process, the appliance reboots and resets itself to the default configuration.
- Once the reset process is complete, you can set up and reconfigure the appliance, as described in Deploying the B1-212 Physical Server.
Important
If you use a USB drive that contains a previously downloaded or created “dofactoryreset” file, ensure that you change the timestamp of the file before resetting your B1-212 appliance. Otherwise, you will not be able to reset the appliance. On a Linux system, you can use the "touch" command to change the timestamp of the file. You can also remove the old file and download a new one from the Infoblox Portal.
Resetting via the Device UI
To reset the B1-212 appliance using the Device UI, do the following:
- Log in to the Infoblox Portal.
- Click Configure > Servers.
- On the Hosts page, select the NIOS-X server you want to configure.
- Click the ... drop-down menu, and then select Local Access to enable local access to the B1-212 appliance.
In the Enable Local Access dialog, click Enable. Local access to the appliance is granted for two hours. Note that enabling local access to the B1-212 appliance allows you to reset the NIOS-X server using the Device UI.
- Log in to the Device UI. For information about the Device UI, see Troubleshooting Servers.
- Click Administration > Reset Host from the left pane menu.
- On the Administration page, click Reset for Factory Reset.
- In the Confirm your action dialog, complete the following:
- Enter your password: Enter the last seven or eight digits of the serial number mentioned on the Service Tag of B1-212 appliance.
- Click Confirm to proceed with the factory reset.
- Once the reset process is complete, you can set up and reconfigure the appliance, as described in Deploying the B1-212 Physical Server.