Reverting to the Previously Running Software Version
You can revert to a version of software that was previously running on your appliance. The appliance stores the previous software version in its backup software partition. You can see if there is a software version to which you can revert and its version number in the Alternate Version column in the Grid Version Information section of the Upgrade tab. To view the software version, from the Master Grid tab, select the Upgrade tab. Note that once you start distributing a new version after an upgrade, you cannot revert to a previous version.
Be aware that when you revert to this software, changes made since the Master Grid was last upgraded are lost. To revert to a version of software previously running on a the Master Grid:
- From the Master Grid tab, select the Upgrade tab, and then click Revert from the Toolbar.
Multi-Grid Manager displays a warning indicating that the revert process disrupts Master Grid services. Read the warning carefully, and then click Yes to confirm your decision to revert.